TST Series 2 Torque Measurement Testers

Pictorial display for easy mode selection "SMART" intelligence for transducer recognition, Transducer capacity, Unit and Serial No. are shown Instrument accuracy ±0.05% (±0.1% when below 10% of transducer capacity) System accuracy with internal transducer or a typical external Norbar transducer, ±0.5% from 20% of transducer capacity Limit Detection with low, pass and fail indication. Up to 12 target values can be set Analogue output allows the instrument to be used as part of a process control system for performance analysis Operation from fast charge internal battery pack (maximum time of 3 hours 20 minutes for full charge) or a.c. supply (90 to 264 Volts) All user selectable features have password protection to virtually eliminate human error RS-232-C serial data interface for connection to a printer or PC User sele
ctable frequency response for each mode of operation Guaranteed classification to BS7882:2017, Class 1 or better over the primary calibration range (20% to 100% of full scale), Class 2 or better over the secondary calibration range (lowest calibrated value to 20% of full scale) Class 1 equates to ±0.5% of reading Made in the UK